        News

        What's the functions of KPM60 motor protector

        Release time:2019-01-14 Times of browsing:


          KPM60 series smart motor protector is suitable for rated voltage 380V to 660V rated current 5A-500A control loop. It has 19 basic protection functions, which could better realize the motor protection and data monitoring.
           
          Because the usage, performance, environment of motors are different, Compere Smart developed this KPM60 smart motor protector in order to avoid user’s inconvenience in protector selection and the extra cost of buying the unnecessary function.

          KPM60 motor protector function selection

          Through a lot of on-site and user research, we add the higher frequency and widely used function into standard selection. And those low frequency and not widely used functions are added to the optional function. In this way, which avoids extra cost of unnecessary functions.

          For example, KPM60 series low voltage motor protector supports the Modbus-RTU and Profibus-DP communication. However, Profibus-DP communication has a small audience and a narrow application field. If the communication is added to the standard configuration, it does not make any sense to the user. Modbus-RTU communication is the popular mainstream communication method. Adding it in the standard configuration, can help users effectively realize the communication of the motor protector.

          The following figure shows the KPM60 standard function configuration table:
           

          Function Content Standard selection Optional Remake
           
           
           
           
          Measurement
           
           
           
           
           
           
          3 phase current    
          3 phase voltage    
          Active power    
          Reactive power   Need to increase voltage function
          Power factor    
          Frequency    
          Active energy    
          Reactive energy    
          Grounding current    
          Leakage current   Need to increase leakage function
          Heat capacity    
           
           
           
           
           
           
           
           
           
          Protection
           
           
           
           
           
           
           
           
           
          Overload protection  
          Stall protection    
          Overheating protection    
          Short circuit protection    
          Current balance protection    
          Start timeout protection    
          Grounding protection    
          Loss phase protection    
          Contactor breaking current protection    
          Underload protection    
          Leakage protection   Need to increase leakage function
          Te protection   Suitable for mounting type motor
          Temperature protection    
          Overload protection    
          Under voltage protection    
          Underpower protection    
          Undervoltage restart   Need to increase voltage function
          Phase sequence protection    
          Power factor protection    
          Communication Modbus-RTU    
          Profibus-DP    
          Analog output 1 way 4~20mA transmitting output, transmitting item programmable   Need to increase analog output
          Switch output 8-way passive dry node optically isolated input    
          Relay output 4 way relay output